Prospective Comparison of Spleen and Liver Stiffness by Using Shear-Wave and Transient Elastography for Detection of Portal Hypertension in Cirrhosis

2014 Radiology -141210

Purpose To prospectively compare the technical success rate and accuracy of shear-wave elastography (SWE) and transient elastography (TE) for the detection of clinically significant portal hypertension (PH) in patients with advanced cirrhosis who are undergoing hepatic vein pressure gradient (HVPG) measurements. Materials and Methods The institutional ethics committee approved the study, and written informed consent was obtained. Seventy-nine consecutive patients with cirrhosis who were undergoing SWE and TE at the time of HVPG measurement were studied. The technical success rate of SWE and TE was compared with the diagnostic value of liver stiffness (LS) and spleen stiffness (SS) measurements and composite scores (LS spleen-diameter-to-platelet-ratio score [LSPS] and PH risk score) by using SWE and TE to detect clinically significant PH (HVPG >/= 10 mm Hg) and esophageal varices at high risk of bleeding. Areas under the receiver operating characteristic curve and the DeLong test were used. Results The technical success rate of SWE was significantly better than that of TE for both LS and SS (97% and 97% vs 44% and 42%, respectively; P